Introducing our advanced hot and cold unit, also known as a thermal circulator, designed for precise temperature control in various applications. This integrated temperature management system combines both refrigeration and heating functions, ensuring stable and accurate temperature regulation. Perfect for laboratories and industrial processes, our hot and cold units are essential for maintaining optimal conditions in reactors, instruments, and testing chambers. As a leading factory and supplier in China, we pride ourselves on delivering high-quality thermal circulators that meet the rigorous demands of both research and manufacturing environments. Experience unparalleled temperature control with our reliable solutions

    Product Description
    🌡️ Temperature Range: -50℃ ~ 300℃
    ⚡ Heating Power: 6KW – 96KW
    ❄️ Cooling Power: 3KW – 200KW

    Basic Functions
    🔥 Heating Part
    Return oil temperature display
    Start-up automatic exhaust
    Heating power gear adjustment
    304 stainless steel integrated pipe — reduces pipe resistance and carbon deposition
    Perfect safety protection & fault display system — no professional personnel needed for repair
    PLC control — high reliability, strong anti-interference ability
    ❄️ Cooling Part
    Brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
    Internal copper pipe welded without oxygen
    High-efficiency evaporator and condenser
    304 SS stainless steel water tank
    PC board self-optimized microprocessor — easy to operate
    OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories with perfect safety

    Core Working Principle
    Its operation is based on a closed-loop circulation system:
    1
    Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
    2
    Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
    3
    Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
    4
    Temperature Regulation:
    • When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
    • When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
    5
    Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within high precision, often ±0.1°C or better.
    💡
    Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.

    Main Features and Advantages
    1
    🏗️ Integrated Design, Saves Space
    Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
    2
    🌡️ Broad Temperature Control Range
    A single unit covers a wide span from low to high temperatures. Common ranges include:
    -80°C ~ +200°C  |  -40°C ~ +200°C
    -25°C ~ +200°C  |  0°C ~ +300°C
    3
    🎯 High-Precision Temperature Control
    Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
    4
    ⚡ High Efficiency and Energy Saving
    The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at lower power to offset it — more efficient than cooling alone. Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
    5
    🚀 Increases Production Efficiency
    Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).

    Main Application Fields
    ⚗️ Chemical & Pharmaceutical Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
    🔩 Plastics & Rubber Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
    🔬 Laboratory & Testing Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
    🔋 New Energy Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
    💻 Semiconductor & Electronics Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
    🍫 Food Industry Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
    🏭 Other Industries Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
    16
    15
    14

    Schematic Diagram
    Schematic Diagram

    Specification
    Parameter UNIT MODEL
    SCR-05A-24O SCR-10AD-36O SCR-05W-24O SCR-10WD-36O SCR-05A-24W SCR-10AD-36W SCR-05W-24W SCR-10WD-36W
    Temp control range ℃ 5℃–300℃ 5℃–120℃
    Temp control accuracy ℃ PID ±1℃
    Power supply / AC380V 50Hz
    Heat transfer medium / Thermo conductive oil Water
    Cooling method / Indirect Cooling Direct Cooling
    Alarm function / Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating
    Compressor type / Piston
    Evaporator type / Submerged Coil Type / Dry Shell And Tube Type
    Condenser type / MCHE Or Finned Tubes Shell And Tube Type MCHE Or Finned Tubes Shell And Tube Type
    Cooling Capacity KW 13.95 28 15.9 31.8 13.95 28 15.9 31.8
    Heating power KW 24 36 24 36 24 36 24 36
    Motor power KW 1.5 2.2 1.5 2.2 1.5 2.2 1.5 2.2
    Pump flow m³/h 6 10 6 10 6 10 6 10
    Pump head m 28 28 28 28 28 28 28 28
    Power Input KW 31 47 30.5 46.5 31 47 30.5 46.5
    Expansion tank capacity L 30 50 30 50 /
    Water tank capacity L 50 110 50 110 50 110 50 110
    Cooling water pipe Inch / 1" 2" / 1" 2"
    Circulating oil pipe Inch 1" 1-1/4" 1" 1-1/4" 1" 1-1/4" 1" 1-1/4"
    Size (L×W×H) mm 1200×1100×1250 1450×1250×1550 1200×1000×1250 1300×1180×1400 1200×1050×1250 1450×1200×1550 1200×950×1250 1300×1130×1400

    Products Detail
    Combined Heating and Cooling Machine01
    Combined Heating and Cooling Machine 02
    Combined Heating and Cooling Machine 03

    Frequently Asked Questions (FAQ)
    Q
    What is the temperature control range of this combined heating and cooling machine?
    The unit supports a temperature control range of -50°C to 300°C, with specific models covering ranges such as -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, and 0°C to +300°C. This broad range makes it suitable for both cryogenic and high-temperature industrial processes.
    Q
    How does the PID temperature control system work and what precision can it achieve?
    The system uses a PID (Proportional-Integral-Derivative) closed-loop control algorithm. A temperature sensor continuously monitors the return fluid temperature and compares it against the set point. The controller then adjusts heating or cooling output in real time. Temperature control accuracy is PID ±1°C, with high-end configurations achieving ±0.1°C or better.
    Q
    What heat transfer media can be used with this unit?
    Depending on the model, the unit supports thermo conductive oil (for high-temperature oil models reaching up to 300°C) or water (for water-based models typically up to 120°C). A glycol-water mixture can also be used for applications requiring sub-zero cooling.
    Q
    What industries and applications is this machine suitable for?
    This combined heating and cooling machine is widely used across multiple industries, including chemical & pharmaceutical (reaction kettles, bioreactors), plastics & rubber (injection molds, extruders), laboratory & testing (rotary evaporators, environmental chambers), new energy (battery & motor testing), semiconductor & electronics (laser cooling, PCB equipment), food industry (chocolate tempering, sterilization cooling), and more.
    Q
    What safety protection features does the unit include?
    The unit is equipped with a comprehensive safety alarm and protection system, including: pump reversal protection, oil shortage alarm, overheating protection, overload protection, oil overflow alarm, and abnormal heating detection. The PLC-based control system ensures high reliability and strong anti-interference capability, and no specialized maintenance personnel are required for routine fault handling.
    Q
    What is the difference between air-cooled and water-cooled condenser models?
    Air-cooled models (e.g., SCR-05A-24O / SCR-05A-24W) use MCHE or finned tube condensers and dissipate heat via ambient air — no cooling water supply is needed, making installation simpler. Water-cooled models (e.g., SCR-05W-24O / SCR-05W-24W) use shell-and-tube condensers and require a cooling water connection, but offer higher efficiency and are better suited for high-load or high-ambient-temperature environments.