0102030405
China Combined Heating and Cooling Machine - Reliable Temperature Control from Leading Suppliers and Factory
Product Description
🌡️
Temperature Range: -50℃ ~ 300℃
⚡
Heating Power: 6KW – 96KW
❄️
Cooling Power: 3KW – 200KW
Basic Functions
🔥 Heating Part
Return oil temperature display
Start-up automatic exhaust
Heating power gear adjustment
304 stainless steel integrated pipe — reduces pipe resistance and carbon deposition
Perfect safety protection & fault display system — no professional personnel needed for repair
PLC control — high reliability, strong anti-interference ability
❄️ Cooling Part
Brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
Internal copper pipe welded without oxygen
High-efficiency evaporator and condenser
304 SS stainless steel water tank
PC board self-optimized microprocessor — easy to operate
OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories with perfect safety
Core Working Principle
Its operation is based on a closed-loop circulation system:
1
Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
2
Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
3
Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
4
Temperature Regulation:
• When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
• When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
• When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
• When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
5
Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within high precision, often ±0.1°C or better.
💡
Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.
Main Features and Advantages
1
🏗️ Integrated Design, Saves Space
Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
2
🌡️ Broad Temperature Control Range
A single unit covers a wide span from low to high temperatures. Common ranges include:
-80°C ~ +200°C | -40°C ~ +200°C
-25°C ~ +200°C | 0°C ~ +300°C
-80°C ~ +200°C | -40°C ~ +200°C
-25°C ~ +200°C | 0°C ~ +300°C
3
🎯 High-Precision Temperature Control
Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
4
⚡ High Efficiency and Energy Saving
The cooling system operates at full capacity for fast cooling. During temperature stabilization, if the process generates heat, the cooling system can run at lower power to offset it — more efficient than cooling alone. Some advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
5
🚀 Increases Production Efficiency
Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
Main Application Fields
⚗️ Chemical & Pharmaceutical
Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
🔩 Plastics & Rubber
Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
🔬 Laboratory & Testing
Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
🔋 New Energy
Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
💻 Semiconductor & Electronics
Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
🍫 Food Industry
Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
🏭 Other Industries
Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃–300℃ | 5℃–120℃ | ||||||
| Temp control accuracy | ℃ | PID ±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dry Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m³/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size (L×W×H) | mm | 1200×1100×1250 | 1450×1250×1550 | 1200×1000×1250 | 1300×1180×1400 | 1200×1050×1250 | 1450×1200×1550 | 1200×950×1250 | 1300×1130×1400 |
Products Detail
Frequently Asked Questions (FAQ)
Q
What is the temperature control range of this combined heating and cooling machine?
The unit supports a temperature control range of -50°C to 300°C, with specific models covering ranges such as -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, and 0°C to +300°C. This broad range makes it suitable for both cryogenic and high-temperature industrial processes.
Q
How does the PID temperature control system work and what precision can it achieve?
The system uses a PID (Proportional-Integral-Derivative) closed-loop control algorithm. A temperature sensor continuously monitors the return fluid temperature and compares it against the set point. The controller then adjusts heating or cooling output in real time. Temperature control accuracy is PID ±1°C, with high-end configurations achieving ±0.1°C or better.
Q
What heat transfer media can be used with this unit?
Depending on the model, the unit supports thermo conductive oil (for high-temperature oil models reaching up to 300°C) or water (for water-based models typically up to 120°C). A glycol-water mixture can also be used for applications requiring sub-zero cooling.
Q
What industries and applications is this machine suitable for?
This combined heating and cooling machine is widely used across multiple industries, including chemical & pharmaceutical (reaction kettles, bioreactors), plastics & rubber (injection molds, extruders), laboratory & testing (rotary evaporators, environmental chambers), new energy (battery & motor testing), semiconductor & electronics (laser cooling, PCB equipment), food industry (chocolate tempering, sterilization cooling), and more.
Q
What safety protection features does the unit include?
The unit is equipped with a comprehensive safety alarm and protection system, including: pump reversal protection, oil shortage alarm, overheating protection, overload protection, oil overflow alarm, and abnormal heating detection. The PLC-based control system ensures high reliability and strong anti-interference capability, and no specialized maintenance personnel are required for routine fault handling.
Q
What is the difference between air-cooled and water-cooled condenser models?
Air-cooled models (e.g., SCR-05A-24O / SCR-05A-24W) use MCHE or finned tube condensers and dissipate heat via ambient air — no cooling water supply is needed, making installation simpler. Water-cooled models (e.g., SCR-05W-24O / SCR-05W-24W) use shell-and-tube condensers and require a cooling water connection, but offer higher efficiency and are better suited for high-load or high-ambient-temperature environments.