0102030405
China Combined Heating and Cooling Machine - Reliable Suppliers and Factory for Precision Temperature Control
Product Description
Temperature Range: -50℃ ~ 300℃
Heating Power: 6KW – 96KW
Cooling Power: 3KW – 200KW
Basic Functions
Heating Part
- Return oil temperature display
- Start up automatic exhaust
- Heating power gear adjustment
- 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
- Perfect safety protection and fault display system — no professional personnel needed for repair and maintenance
- PLC control, high reliability, strong anti-interference ability
Cooling Part
- Brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
- Internal copper pipe welded without oxygen
- High efficiency evaporator and condenser
- 304 SS stainless steel water tank
- PC board self-optimized microprocessor, easy to operate
- OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS and other brand accessories
Core Working Principle
Its operation is based on a closed-loop circulation system:
- 1. Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
- 2. Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
- 3. Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
-
4. Temperature Regulation:
• When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid. • When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature. - 5. Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within high precision, often ±0.1°C or better.
⚡ Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.
Main Features and Advantages
🏗️
1. Integrated Design, Saves Space
Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
🌡️
2. Broad Temperature Control Range
A single unit covers a wide span from low to high temperatures. Common ranges: -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, 0°C to +300°C.
🎯
3. High-Precision Temperature Control
Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
⚡
4. High Efficiency and Energy Saving
The cooling system operates at full capacity for fast cooling. During temperature stabilization, it runs at lower power to offset heat. Some advanced models recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
🚀
5. Increases Production Efficiency
Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
Main Application Fields
- ⚗️ Chemical & Pharmaceutical Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control.
- 🔩 Plastics & Rubber Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control.
- 🔬 Laboratory & Testing Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing.
- 🔋 New Energy Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing.
- 💻 Semiconductor & Electronics Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control.
- 🍫 Food Industry Food production line temperature control, chocolate tempering, rapid cooling after can sterilization.
- 🏭 Other Industries Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃-300℃ | 5℃-120℃ | ||||||
| Temp control accuracy | ℃ | PID±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dny Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m³/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size (L×W×H) | mm | 1200×1100×1250 | 1450×1250×1550 | 1200×1000×1250 | 1300×1180×1400 | 1200×1050×1250 | 1450×1200×1550 | 1200×950×1250 | 1300×1130×1400 |
Products Detail
Frequently Asked Questions (FAQ)
Q
What is the temperature control range of this combined heating and cooling machine?
The unit supports a temperature control range of -50°C to 300°C, with heating power from 6KW to 96KW and cooling power from 3KW to 200KW. Specific model configurations cover ranges such as -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, and 0°C to +300°C.
Q
What heat transfer mediums are compatible with this unit?
The unit supports multiple heat transfer mediums depending on the model. Oil-type models use thermo conductive oil (suitable for high-temperature applications up to 300°C), while water-type models use water (suitable for applications up to 120°C). A glycol-water mixture can also be used for sub-zero temperature applications.
Q
How accurate is the temperature control, and what control method is used?
The system uses PID (Proportional-Integral-Derivative) intelligent control with a standard accuracy of ±1°C. Advanced configurations can achieve precision as high as ±0.1°C or better, making it suitable for laboratory, pharmaceutical, and semiconductor applications with stringent temperature requirements.
Q
What industries and applications is this machine suitable for?
This combined unit is widely used across multiple industries, including Chemical & Pharmaceutical (reaction kettles, bioreactors), Plastics & Rubber (injection molds, extruders), Laboratory & Testing (rotary evaporators, environmental chambers), New Energy (battery and fuel cell testing), Semiconductor & Electronics (laser cooling, PCB equipment), Food Industry (chocolate tempering, sterilization cooling), and more.
Q
What safety protection features does the unit include?
The unit is equipped with a comprehensive safety protection and fault display system, including alarms for: pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating. The system is designed so that no professional personnel are required for routine repair and maintenance.
Q
What is the difference between the air-cooled and water-cooled condenser models?
Models with air-cooled condensers (MCHE or Finned Tubes) are suitable for environments where a cooling water supply is not available or practical — they dissipate heat directly into the ambient air. Models with water-cooled condensers (Shell and Tube Type) require a cooling water supply but offer higher efficiency and are better suited for high-load or high-ambient-temperature environments.