0102030405
China Combined Heating and Cooling Machine - High-Quality Thermal Circulator from Reliable Suppliers and Factory
Product Description
🌡️ Temperature Range: -50℃ ~ 300℃
⚡ Heating Power: 6KW – 96KW
❄️ Cooling Power: 3KW – 200KW
Basic Functions
🔥 Heating Part
- Return oil temperature display
- Start-up automatic exhaust
- Heating power gear adjustment
- 304 stainless steel integrated pipe to reduce pipe resistance and carbon deposition
- Perfect safety protection and fault display system — no professional personnel needed for repair
- PLC control with high reliability and strong anti-interference ability
❄️ Cooling Part
- Brand scroll compressor: Grain Wheel, Sanyo, Daikin, etc.
- Internal copper pipe welded without oxygen
- High-efficiency evaporator and condenser
- 304 SS stainless steel water tank
- PC board self-optimized microprocessor, easy to operate
- Premium brand accessories: OMRON, FUJI, TE, LG, ABB, SCHNEIDER, SIEMENS
Core Working Principle
Its operation is based on a closed-loop circulation system:
-
1Circulating Medium: The unit has an internal reservoir filled with a heat transfer fluid (typically water, a glycol-water mixture, or thermal oil).
-
2Pumping: A circulating pump moves the fluid from the unit to the external equipment requiring temperature control (e.g., reactor jacket, mold channels, test chamber).
-
3Heat Exchange: The fluid absorbs or releases heat within the external equipment, thereby changing its temperature.
-
4Temperature Regulation:
- When heating is required: The built-in electric heater activates to provide supplemental heating to the returning warm fluid or to heat cool fluid.
- When cooling is required: The built-in compressor-based refrigeration system activates to cool the returning warm fluid down to the set temperature.
-
5Return and Feedback: The fluid, having completed heat exchange, returns to the unit and passes a temperature sensor. The control system (using PID logic) compares the set temperature with the return temperature and precisely decides in real-time whether to initiate heating or cooling. This ensures the output fluid temperature remains constant within high precision, often ±0.1°C or better.
⚡ Key Point: The heating and cooling systems work in coordination to quickly offset excess process heat or compensate for heat loss, enabling rapid temperature ramping and precise temperature stabilization.
Main Features and Advantages
🏗️ 1. Integrated Design, Saves Space
Eliminates the need to purchase separate heating and chilling units, simplifying installation and reducing piping connections.
📏 2. Broad Temperature Control Range
A single unit covers a wide span. Common ranges include:
-80°C to +200°C | -40°C to +200°C
-25°C to +200°C | 0°C to +300°C
-80°C to +200°C | -40°C to +200°C
-25°C to +200°C | 0°C to +300°C
🎯 3. High-Precision Temperature Control
Utilizes PID intelligent control for minimal temperature fluctuation, meeting stringent process requirements.
💡 4. High Efficiency and Energy Saving
Refrigeration Power Utilization: The cooling system operates at full capacity for fast cooling. During temperature stabilization, it can run at lower power to offset process-generated heat — more efficient than cooling alone.
Heat Management: Advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
Heat Management: Advanced models can recover waste heat from the refrigeration system for pre-heating, further reducing energy consumption.
🚀 5. Increases Production Efficiency
Rapid heating and cooling rates shorten production cycles (e.g., mold pre-heating and cooling times).
Main Application Fields
| 🧪 Chemical & Pharmaceutical | Precise temperature control for reaction kettles, distillation condensation, process material cooling, bioreactor/fermenter control, GMP process temperature control. |
| 🏭 Plastics & Rubber | Temperature control for injection molds (rapid heat cycling for high-gloss finishes), die-casting mold temperature control, extruder roller temperature control. |
| 🔬 Laboratory & Testing | Cooling for rotary evaporators, reaction calorimeters, bioreactors, supporting environmental test chambers, material high/low-temperature testing. |
| 🔋 New Energy | Battery testing (thermal simulation during charge/discharge), motor testing, hydrogen fuel cell testing. |
| 💻 Semiconductor & Electronics | Laser cooling, semiconductor packaging equipment temperature control, PCB production equipment temperature control. |
| 🍫 Food Industry | Food production line temperature control, chocolate tempering, rapid cooling after can sterilization. |
| 🖨️ Other Industries | Printing roller temperature control, calendering machine temperature control, vacuum coating equipment cooling. |
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||
| SCR-05A-24O | SCR-10AD-36O | SCR-05W-24O | SCR-10WD-36O | SCR-05A-24W | SCR-10AD-36W | SCR-05W-24W | SCR-10WD-36W | ||
| Temp control range | ℃ | 5℃–300℃ | 5℃–120℃ | ||||||
| Temp control accuracy | ℃ | PID ±1℃ | |||||||
| Power supply | / | AC380V 50Hz | |||||||
| Heat transfer medium | / | Thermo conductive oil | Water | ||||||
| Cooling method | / | Indirect Cooling | Direct Cooling | ||||||
| Alarm function | / | Pump reversal / Oil shortage / Overheating / Overload / Oil overflow / Abnormal heating | |||||||
| Compressor type | / | Piston | |||||||
| Evaporator type | / | Submerged Coil Type / Dry Shell And Tube Type | |||||||
| Condenser type | / | MCHE Or Finned Tubes | Shell And Tube Type | MCHE Or Finned Tubes | Shell And Tube Type | ||||
| Cooling Capacity | KW | 13.95 | 28 | 15.9 | 31.8 | 13.95 | 28 | 15.9 | 31.8 |
| Heating power | KW | 24 | 36 | 24 | 36 | 24 | 36 | 24 | 36 |
| Motor power | KW | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 | 1.5 | 2.2 |
| Pump flow | m³/h | 6 | 10 | 6 | 10 | 6 | 10 | 6 | 10 |
| Pump head | m | 28 | 28 | 28 | 28 | 28 | 28 | 28 | 28 |
| Power Input | KW | 31 | 47 | 30.5 | 46.5 | 31 | 47 | 30.5 | 46.5 |
| Expansion tank capacity | L | 30 | 50 | 30 | 50 | / | |||
| Water tank capacity | L | 50 | 110 | 50 | 110 | 50 | 110 | 50 | 110 |
| Cooling water pipe | Inch | / | 1" | 2" | / | 1" | 2" | ||
| Circulating oil pipe | Inch | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" | 1" | 1-1/4" |
| Size (L×W×H) | mm | 1200×1100×1250 | 1450×1250×1550 | 1200×1000×1250 | 1300×1180×1400 | 1200×1050×1250 | 1450×1200×1550 | 1200×950×1250 | 1300×1130×1400 |
Products Detail
Frequently Asked Questions (FAQ)
Q
What is the temperature control range of this combined heating and cooling machine?
The unit supports a temperature range of -50°C to 300°C, covering both low-temperature and high-temperature applications. Specific models offer ranges such as -80°C to +200°C, -40°C to +200°C, -25°C to +200°C, and 0°C to +300°C, making it suitable for a wide variety of industrial processes.
Q
What heat transfer media can be used with this unit?
Depending on the model, the unit supports either thermo conductive oil (for high-temperature models up to 300°C) or water (for water-based models up to 120°C). A glycol-water mixture can also be used for low-temperature applications to prevent freezing.
Q
How precise is the temperature control of this machine?
The machine uses PID intelligent control logic with a standard accuracy of ±1°C. Advanced configurations can achieve precision of ±0.1°C or better, making it ideal for sensitive chemical, pharmaceutical, and laboratory processes.
Q
What industries is this combined heating and cooling unit suitable for?
This unit is widely used across multiple industries including chemical & pharmaceutical (reaction kettle control, GMP processes), plastics & rubber (injection mold temperature control), laboratory & testing (rotary evaporators, bioreactors), new energy (battery and fuel cell testing), semiconductor & electronics (laser cooling, PCB production), and the food industry (chocolate tempering, sterilization cooling).
Q
What safety protection features does this machine include?
The unit is equipped with a comprehensive alarm and protection system that monitors for: pump reversal, oil shortage, overheating, overload, oil overflow, and abnormal heating. The fault display system is designed to be user-friendly, requiring no professional technician for routine maintenance and troubleshooting.
Q
What is the difference between air-cooled and water-cooled condenser models?
Models with air-cooled condensers (MCHE or finned tubes) do not require an external cooling water supply, making installation simpler and more flexible. Water-cooled condenser models (shell and tube type) use a cooling water pipe connection (1" or 2") and are generally more efficient in high-ambient-temperature environments or where continuous high-load operation is required.