China Air Cooled Water Chiller Factory - Efficient Low-Temperature Cooling Solutions from Trusted Suppliers
Product Feature
- Adopt compressor imported from Europe and America
- The copper pipe adopts oxygen free welding method
- RS485 communication function to realize automatic management (optional)
- Imported advanced components with long service life
- Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
- Control mode: imported microcomputer or PLC control (optional)
- Perfect safety protection, fault display, repair and maintenance without professional personnel
- High efficiency evaporator and condenser can save energy by more than 30%
Working Principle and System Components
1 Refrigeration Cycle (consistent with all compression refrigeration systems)
- Refrigerant absorbs heat from the chilled water in the evaporator, vaporizing into a gas.
- The low-temperature, low-pressure refrigerant vapor is compressed into a high-temperature, high-pressure gas by the compressor.
- The high-temperature, high-pressure gas enters the air-cooled condenser, where it releases heat and condenses into a high-pressure liquid through forced convection from fan-driven ambient air.
- The high-pressure liquid passes through the expansion valve, throttling into a low-temperature, low-pressure wet vapor, which re-enters the evaporator, completing the cycle.
2 Core Difference — The Air-Cooled Condenser
- This is the fundamental distinction between air-cooled and water-cooled chillers. It consists of copper tube-aluminum fin coil arrays and one or multiple high-power axial fans.
- The fans force air across the finned coils, transferring heat from the high-temperature refrigerant inside the tubes to the atmosphere.
3 System Composition (Highly Integrated)
- Main Unit: The compressor, air-cooled condenser, evaporator, expansion valve, and control system are all integrated within a single steel frame.
- Auxiliary Components:
- Chilled Water Circulation Pump: Typically built into the water tank or provided as an external pump set.
- Insulated Water Tank: Stores chilled water and acts as a buffer for system water volume and temperature stability.
- Electrical Control Cabinet: Integrates control, protection, and display functions.
Typical Industrial Applications
🏭
Plastics Industry
Cooling for injection molding machine molds, directly impacting product quality and cycle time.
⚗️
Chemical & Pharmaceutical
Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
🔧
Machining & Lasers
Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
🍶
Food & Beverage
Cooling for mixing, fermentation, and packaging processes in production lines.
💡
Electronics Industry
Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
⚡
Energy & Metallurgy
Transformer oil cooling, blast furnace auxiliary system cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||||||
| SC-03AS | SC-05AS | SC-08AS | SC-10AD | SC-15AD | SC-20AD | SC-25AD | SC-30AD | SC-40AD | SC-50AD | SC-60AD | |||
| Cooling Capacity | Kcal/h | 7216 | 11990 | 18748 | 24089 | 37965 | 50808.8 | 61683 | 74992 | 97678 | 116521 | 156249 | |
| KW | 8.39 | 13.95 | 21.8 | 28.01 | 44.15 | 59.08 | 71.72 | 87.2 | 113.58 | 135.49 | 181.68 | ||
| Power Input | KW | 3.6 | 5.5 | 8.6 | 11 | 17 | 22.8 | 27.7 | 33.7 | 42.8 | 51.1 | 68.8 | |
| Running Current | A | 8.8 | 13.4 | 20.9 | 26.7 | 41.3 | 55.4 | 63.1 | 76.8 | 97.5 | 116.5 | 143.1 | |
| Refrigerant | / | R22 | |||||||||||
| Power Supply Type | / | 3PH-380V-50HZ | |||||||||||
| Safety Protection Device | / | Overload、Inverse Phase、High/Low Pressure、Low Level、Antifreeze Protection, etc | |||||||||||
| Compressor | Power | KW | 2.25 | 3.75 | 3*2 | 3.75*2 | 7.5+3.75 | 7.5*2 | 9.4*2 | 7.5*3 | 7.5*4 | 9*4 | 7.5*6 |
| Current | A | 4.8 | 9.2 | 15.2 | 17.2 | 41.3 | 36 | 50 | 54 | 66 | 80 | 99 | |
| Pump | Flow | m³/h | 4 | 4 | 8 | 8 | 12 | 16 | 20 | 36 | 36 | 36 | 36 |
| Phead | m | 22 | 22 | 27 | 27 | 31 | 33 | 21 | 20 | 20 | 20 | 20 | |
| Power | KW | 0.55 | 0.55 | 1.1 | 1.3 | 1.85 | 2.6 | 2.2 | 4 | 4 | 4 | 4 | |
| Condenser | Type | / | MCHE Or Finned Tubes | ||||||||||
| Air Flow | m³/h | 3000 | 5000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | 40000 | 50000 | 60000 | |
| Fan Power | KW | 0.24 | 0.4 | 0.64 | 0.8 | 1.2 | 1.6 | 2 | 2.4 | 3.2 | 3.8 | 4 | |
| Evaporator | Type | / | Submerged Coil Type | Dny Shell And Tube Type | |||||||||
| In/Out Pipe Size | Inch | DN25 | DN25 | DN40 | DN50 | DN50 | DN50 | DN65 | DN65 | DN80 | DN80 | DN80 | |
| Tank Volume | L | 45 | 50 | 110 | 110 | 200 | 260 | 310 | 220 | 255 | 280 | 350 | |
| Size | Length | mm | 960 | 1050 | 1480 | 1480 | 1880 | 2000 | 2000 | 2400 | 2100 | 2450 | 3400 |
| Width | mm | 560 | 610 | 720 | 720 | 800 | 900 | 1000 | 1100 | 1600 | 1750 | 1800 | |
| Height | mm | 1250 | 1300 | 1550 | 1550 | 1700 | 1800 | 1950 | 1950 | 1850 | 2050 | 2100 | |
Products Detail
Frequently Asked Questions (FAQ)
Q What is an air-cooled water chiller and how does it differ from a water-cooled chiller?
An air-cooled water chiller uses ambient air — forced by axial fans across copper tube-aluminum fin condenser coils — to dissipate heat from the refrigerant. Unlike water-cooled chillers, it requires no cooling tower or external water supply for the condenser side, making installation simpler and more suitable for locations where water resources are limited.
Q What industries are air-cooled water chillers commonly used in?
Air-cooled water chillers are widely applied across plastics injection molding, chemical and pharmaceutical processing, CNC machining and laser equipment cooling, food and beverage production, electronics and semiconductor manufacturing, as well as energy and metallurgy sectors including transformer oil cooling and blast furnace auxiliary systems.
Q What refrigerant does this chiller series use?
All models in the SC series use R22 refrigerant. The system operates on a standard vapor-compression refrigeration cycle consisting of the evaporator, compressor, air-cooled condenser, and expansion valve.
Q What power supply is required for these chiller units?
All models in this series require a three-phase power supply: 3PH – 380V – 50Hz. Please ensure your facility's electrical infrastructure meets this specification before installation.
Q What safety protection features are built into the chiller?
The chiller is equipped with comprehensive safety protection including overload protection, inverse phase protection, high/low pressure protection, low water level protection, and antifreeze protection. The fault display system allows maintenance without requiring specialized professional personnel on-site.
Q Can the chiller be integrated into an automated management system?
Yes. The chiller offers an optional RS485 communication interface, enabling integration with building management systems (BMS) or factory automation platforms for remote monitoring and automatic management. The control system supports both imported microcomputer and PLC control options.