Product Feature
- Adopt compressor imported from Europe and America
- The copper pipe adopts oxygen free welding method
- RS485 communication function to realize automatic management (optional)
- Imported advanced components with long service life
- Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
- Control mode: imported microcomputer or PLC control (optional)
- Perfect safety protection, fault display, repair and maintenance without professional personnel
- High efficiency evaporator and condenser can save energy by more than 30%
Working Principle and System Components
1
Refrigeration Cycle (consistent with all compression refrigeration systems)
- Refrigerant absorbs heat from the chilled water in the evaporator, vaporizing into a gas.
- The low-temperature, low-pressure refrigerant vapor is compressed into a high-temperature, high-pressure gas by the compressor.
- The high-temperature, high-pressure gas enters the air-cooled condenser, where it releases heat and condenses into a high-pressure liquid through forced convection from fan-driven ambient air.
- The high-pressure liquid passes through the expansion valve, throttling into a low-temperature, low-pressure wet vapor, which re-enters the evaporator, completing the cycle.
2
Core Difference — The Air-Cooled Condenser
- This is the fundamental distinction between air-cooled and water-cooled chillers. It consists of copper tube-aluminum fin coil arrays and one or multiple high-power axial fans.
- The fans force air across the finned coils, transferring heat from the high-temperature refrigerant inside the tubes to the atmosphere.
3
System Composition (Highly Integrated)
- Main Unit: The compressor, air-cooled condenser, evaporator, expansion valve, and control system are all integrated within a single steel frame.
- Auxiliary Components:
- Chilled Water Circulation Pump: Typically built into the water tank or provided as an external pump set.
- Insulated Water Tank: Stores chilled water and acts as a buffer for system water volume and temperature stability.
- Electrical Control Cabinet: Integrates control, protection, and display functions.
Typical Industrial Applications
🏭
Plastics Industry
Cooling for injection molding machine molds, directly impacting product quality and cycle time.
⚗️
Chemical & Pharmaceutical
Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
🔩
Machining & Lasers
Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
🍶
Food & Beverage
Cooling for mixing, fermentation, and packaging processes in production lines.
💡
Electronics Industry
Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
⚡
Energy & Metallurgy
Transformer oil cooling, blast furnace auxiliary system cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||||||
| SC-03AS | SC-05AS | SC-08AS | SC-10AD | SC-15AD | SC-20AD | SC-25AD | SC-30AD | SC-40AD | SC-50AD | SC-60AD | |||
| Cooling Capacity | Kcal/h | 7216 | 11990 | 18748 | 24089 | 37965 | 50808.8 | 61683 | 74992 | 97678 | 116521 | 156249 | |
| KW | 8.39 | 13.95 | 21.8 | 28.01 | 44.15 | 59.08 | 71.72 | 87.2 | 113.58 | 135.49 | 181.68 | ||
| Power Input | KW | 3.6 | 5.5 | 8.6 | 11 | 17 | 22.8 | 27.7 | 33.7 | 42.8 | 51.1 | 68.8 | |
| Running Current | A | 8.8 | 13.4 | 20.9 | 26.7 | 41.3 | 55.4 | 63.1 | 76.8 | 97.5 | 116.5 | 143.1 | |
| Refrigerant | / | R22 | |||||||||||
| Power Supply Type | / | 3PH-380V-50HZ | |||||||||||
| Safety Protection Device | / | Overload、Inverse Phase、High/Low Pressure、Low Level、Antifreeze Protection, etc | |||||||||||
| Compressor | Power | KW | 2.25 | 3.75 | 3*2 | 3.75*2 | 7.5+3.75 | 7.5*2 | 9.4*2 | 7.5*3 | 7.5*4 | 9*4 | 7.5*6 |
| Current | A | 4.8 | 9.2 | 15.2 | 17.2 | 41.3 | 36 | 50 | 54 | 66 | 80 | 99 | |
| Pump | Flow | m³/h | 4 | 4 | 8 | 8 | 12 | 16 | 20 | 36 | 36 | 36 | 36 |
| Phead | m | 22 | 22 | 27 | 27 | 31 | 33 | 21 | 20 | 20 | 20 | 20 | |
| Power | KW | 0.55 | 0.55 | 1.1 | 1.3 | 1.85 | 2.6 | 2.2 | 4 | 4 | 4 | 4 | |
| Condenser | Type | / | MCHE Or Finned Tubes | ||||||||||
| Air Flow | m³/h | 3000 | 5000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | 40000 | 50000 | 60000 | |
| Fan Power | KW | 0.24 | 0.4 | 0.64 | 0.8 | 1.2 | 1.6 | 2 | 2.4 | 3.2 | 3.8 | 4 | |
| Evaporator | Type | / | Submerged Coil Type | Dny Shell And Tube Type | |||||||||
| In/Out Pipe Size | Inch | DN25 | DN25 | DN40 | DN50 | DN50 | DN50 | DN65 | DN65 | DN80 | DN80 | DN80 | |
| Tank Volume | L | 45 | 50 | 110 | 110 | 200 | 260 | 310 | 220 | 255 | 280 | 350 | |
| Size | Length | mm | 960 | 1050 | 1480 | 1480 | 1880 | 2000 | 2000 | 2400 | 2100 | 2450 | 3400 |
| Width | mm | 560 | 610 | 720 | 720 | 800 | 900 | 1000 | 1100 | 1600 | 1750 | 1800 | |
| Height | mm | 1250 | 1300 | 1550 | 1550 | 1700 | 1800 | 1950 | 1950 | 1850 | 2050 | 2100 | |
Products Detail
Frequently Asked Questions
QWhat is an air-cooled water chiller and how does it work?
An air-cooled water chiller is a refrigeration system that uses ambient air to dissipate heat from the refrigerant via an air-cooled condenser with finned coil arrays and axial fans. The refrigerant absorbs heat from the process water in the evaporator, is compressed into high-temperature gas, releases heat to the air through the condenser, and then cycles back through the expansion valve — continuously cooling the chilled water loop.
QWhat is the difference between air-cooled and water-cooled chillers?
The core difference lies in how heat is rejected. Air-cooled chillers use ambient air and built-in fans to cool the condenser, making them easier to install with no cooling tower required. Water-cooled chillers use a separate cooling water circuit and cooling tower, offering higher efficiency but requiring more infrastructure and maintenance.
QWhat industries are air-cooled water chillers suitable for?
Air-cooled water chillers are widely used across many industries including plastics (injection molding), chemical and pharmaceutical processing, CNC machining and laser equipment, food and beverage production, electronics manufacturing (semiconductor and ultrasonic cleaning), and energy and metallurgy sectors such as transformer oil cooling.
QWhat models are available and what is the cooling capacity range?
The SC series air-cooled chillers range from SC-03AS to SC-60AD, covering cooling capacities from approximately 8.39 KW (SC-03AS) up to 181.68 KW (SC-60AD). This wide range makes them suitable for small workshop applications as well as large-scale industrial processes.
QWhat safety protection features are included?
These chillers are equipped with comprehensive safety protection systems including overload protection, inverse phase protection, high/low pressure protection, low water level protection, and antifreeze protection. The fault display system allows for easy diagnosis and maintenance without requiring specialized technical personnel on-site.
QCan the chiller be integrated into an automated management system?
Yes. The chiller supports RS485 communication (optional), enabling integration with building management systems or factory automation platforms for remote monitoring and automatic management. The control system can also be optionally configured with an imported microcomputer controller or PLC control for advanced automation needs.