Leave Your Message

China Air Cooled Water Chiller - Efficient Cooling Solutions from Trusted Suppliers and Factory

,

Introducing our advanced water chiller, designed for optimal efficiency and reliability. This compact unit seamlessly integrates a refrigeration system, water tank, and water pump, making installation straightforward and enhancing cooling performance. The water chiller effectively reduces circulating water to the desired low temperature, ensuring a consistent supply of chilled water for various industrial applications. As a leading provider in China, we, as trusted suppliers and factory, guarantee high-quality standards and exceptional service to meet your cooling needs.

,

    Product Feature
    • Adopt compressor imported from Europe and America
    • The copper pipe adopts oxygen free welding method
    • RS485 communication function to realize automatic management (optional)
    • Imported advanced components with long service life
    • Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
    • Control mode: imported microcomputer or PLC control (optional)
    • Perfect safety protection, fault display, repair and maintenance without professional personnel
    • High efficiency evaporator and condenser can save energy by more than 30%
    Working Principle and System Components
    1 Refrigeration Cycle (consistent with all compression refrigeration systems)
    • Refrigerant absorbs heat from the chilled water in the evaporator, vaporizing into a gas.
    • The low-temperature, low-pressure refrigerant vapor is compressed into a high-temperature, high-pressure gas by the compressor.
    • The high-temperature, high-pressure gas enters the air-cooled condenser, where it releases heat and condenses into a high-pressure liquid through forced convection from fan-driven ambient air.
    • The high-pressure liquid passes through the expansion valve, throttling into a low-temperature, low-pressure wet vapor, which re-enters the evaporator, completing the cycle.
    2 Core Difference — The Air-Cooled Condenser
    • This is the fundamental distinction between air-cooled and water-cooled chillers. It consists of copper tube-aluminum fin coil arrays and one or multiple high-power axial fans.
    • The fans force air across the finned coils, transferring heat from the high-temperature refrigerant inside the tubes to the atmosphere.
    3 System Composition (Highly Integrated)
    • Main Unit: The compressor, air-cooled condenser, evaporator, expansion valve, and control system are all integrated within a single steel frame.
    • Auxiliary Components:
    • Chilled Water Circulation Pump: Typically built into the water tank or provided as an external pump set.
    • Insulated Water Tank: Stores chilled water and acts as a buffer for system water volume and temperature stability.
    • Electrical Control Cabinet: Integrates control, protection, and display functions.
    Typical Industrial Applications
    🏭
    Plastics Industry Cooling for injection molding machine molds, directly impacting product quality and cycle time.
    ⚗️
    Chemical & Pharmaceutical Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
    🔧
    Machining & Lasers Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
    🍔
    Food & Beverage Cooling for mixing, fermentation, and packaging processes in production lines.
    💡
    Electronics Industry Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
    ⚡
    Energy & Metallurgy Transformer oil cooling, blast furnace auxiliary system cooling.
    16
    15
    14
    Schematic Diagram
    Schematic Diagram
    Specification
    Parameter UNIT MODEL
    SC-03AS SC-05AS SC-08AS SC-10AD SC-15AD SC-20AD SC-25AD SC-30AD SC-40AD SC-50AD SC-60AD
    Cooling Capacity Kcal/h 7216 11990 18748 24089 37965 50808.8 61683 74992 97678 116521 156249
    KW 8.39 13.95 21.8 28.01 44.15 59.08 71.72 87.2 113.58 135.49 181.68
    Power Input KW 3.6 5.5 8.6 11 17 22.8 27.7 33.7 42.8 51.1 68.8
    Running Current A 8.8 13.4 20.9 26.7 41.3 55.4 63.1 76.8 97.5 116.5 143.1
    Refrigerant / R22
    Power Supply Type / 3PH-380V-50HZ
    Safety Protection Device / Overload、Inverse Phase、High/Low Pressure、Low Level、Antifreeze Protection, etc
    Compressor Power KW 2.25 3.75 3*2 3.75*2 7.5+3.75 7.5*2 9.4*2 7.5*3 7.5*4 9*4 7.5*6
    Current A 4.8 9.2 15.2 17.2 41.3 36 50 54 66 80 99
    Pump Flow m³/h 4 4 8 8 12 16 20 36 36 36 36
    Phead m 22 22 27 27 31 33 21 20 20 20 20
    Power KW 0.55 0.55 1.1 1.3 1.85 2.6 2.2 4 4 4 4
    Condenser Type / MCHE Or Finned Tubes
    Air Flow m³/h 3000 5000 8000 10000 15000 20000 25000 30000 40000 50000 60000
    Fan Power KW 0.24 0.4 0.64 0.8 1.2 1.6 2 2.4 3.2 3.8 4
    Evaporator Type / Submerged Coil Type Dny Shell And Tube Type
    In/Out Pipe Size Inch DN25 DN25 DN40 DN50 DN50 DN50 DN65 DN65 DN80 DN80 DN80
    Tank Volume L 45 50 110 110 200 260 310 220 255 280 350
    Size Length mm 960 1050 1480 1480 1880 2000 2000 2400 2100 2450 3400
    Width mm 560 610 720 720 800 900 1000 1100 1600 1750 1800
    Height mm 1250 1300 1550 1550 1700 1800 1950 1950 1850 2050 2100
    Products Detail
    air cooled water chiller
    industrial water chiller
    Water chiller
    Frequently Asked Questions (FAQ)
    Q What is the difference between an air-cooled chiller and a water-cooled chiller?
    An air-cooled chiller uses ambient air — driven by axial fans across finned coil condensers — to dissipate heat from the refrigerant. A water-cooled chiller uses a separate cooling water circuit and a cooling tower to reject heat. Air-cooled chillers are easier to install, require no cooling tower, and are ideal for locations where water resources are limited.
    Q What refrigerant does this air-cooled chiller use, and what is the power supply requirement?
    All models in the SC series use R22 refrigerant. The standard power supply is 3-phase, 380V, 50Hz. Please ensure your facility's electrical supply matches these specifications before installation.
    Q What safety protection features are included in these chillers?
    The chillers are equipped with comprehensive safety protection including overload protection, inverse phase protection, high/low pressure protection, low water level protection, and antifreeze protection. Fault codes are displayed on the control panel, allowing maintenance without the need for specialized personnel.
    Q Can the chiller be integrated into an automated production management system?
    Yes. The chiller supports RS485 communication (optional), enabling integration with factory automation and SCADA systems for remote monitoring and automatic management. PLC control is also available as an optional upgrade over the standard microcomputer controller.
    Q How much energy can these chillers save compared to standard units?
    Thanks to high-efficiency evaporators and condensers, these air-cooled chillers can achieve energy savings of more than 30% compared to conventional units. The use of imported European and American compressors and premium electrical components further contributes to long-term operational efficiency.
    Q Which industries and applications are these air-cooled chillers suitable for?
    These chillers are widely used across multiple industries, including plastics (injection molding cooling), chemical and pharmaceutical (reaction vessel cooling), machining and laser equipment (CNC spindle and laser source cooling), food and beverage production, electronics and semiconductor manufacturing, and energy and metallurgy sectors such as transformer oil cooling and blast furnace auxiliary systems.