0102030405
China Air Cooled Water Chiller - Efficient Cooling Solutions from Reliable Suppliers & Factory
Product Feature
- ✔ Adopt compressor imported from Europe and America.
- ✔ The copper pipe adopts oxygen free welding method.
- ✔ RS485 communication function to realize automatic management (optional).
- ✔ Imported advanced components with long service life.
- ✔ Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances.
- ✔ Control mode: imported microcomputer or PLC control (optional).
- ✔ Perfect safety protection, fault display, repair and maintenance without professional personnel.
- ✔ High efficiency evaporator and condenser can save energy by more than 30%.
Working Principle and System Components
1
Refrigeration Cycle (consistent with all compression refrigeration systems)
- Refrigerant absorbs heat from the chilled water in the evaporator, vaporizing into a gas.
- The low-temperature, low-pressure refrigerant vapor is compressed into a high-temperature, high-pressure gas by the compressor.
- The high-temperature, high-pressure gas enters the air-cooled condenser, where it releases heat and condenses into a high-pressure liquid through forced convection from fan-driven ambient air.
- The high-pressure liquid passes through the expansion valve, throttling into a low-temperature, low-pressure wet vapor, which re-enters the evaporator, completing the cycle.
2
Core Difference — The Air-Cooled Condenser
- This is the fundamental distinction between air-cooled and water-cooled chillers. It consists of copper tube-aluminum fin coil arrays and one or multiple high-power axial fans.
- The fans force air across the finned coils, transferring heat from the high-temperature refrigerant inside the tubes to the atmosphere.
3
System Composition (Highly Integrated)
- Main Unit: The compressor, air-cooled condenser, evaporator, expansion valve, and control system are all integrated within a single steel frame.
- Auxiliary Components:
- Chilled Water Circulation Pump: Typically built into the water tank or provided as an external pump set.
- Insulated Water Tank: Stores chilled water and acts as a buffer for system water volume and temperature stability.
- Electrical Control Cabinet: Integrates control, protection, and display functions.
Typical Industrial Applications
🏭
Plastics Industry
Cooling for injection molding machine molds, directly impacting product quality and cycle time.
⚗️
Chemical & Pharmaceutical
Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
🔧
Machining & Lasers
Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
🍶
Food & Beverage
Cooling for mixing, fermentation, and packaging processes in production lines.
💡
Electronics Industry
Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
⚡
Energy & Metallurgy
Transformer oil cooling, blast furnace auxiliary system cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||||||
| SC-03AS | SC-05AS | SC-08AS | SC-10AD | SC-15AD | SC-20AD | SC-25AD | SC-30AD | SC-40AD | SC-50AD | SC-60AD | |||
| Cooling Capacity | Kcal/h | 7216 | 11990 | 18748 | 24089 | 37965 | 50808.8 | 61683 | 74992 | 97678 | 116521 | 156249 | |
| KW | 8.39 | 13.95 | 21.8 | 28.01 | 44.15 | 59.08 | 71.72 | 87.2 | 113.58 | 135.49 | 181.68 | ||
| Power Input | KW | 3.6 | 5.5 | 8.6 | 11 | 17 | 22.8 | 27.7 | 33.7 | 42.8 | 51.1 | 68.8 | |
| Running Current | A | 8.8 | 13.4 | 20.9 | 26.7 | 41.3 | 55.4 | 63.1 | 76.8 | 97.5 | 116.5 | 143.1 | |
| Refrigerant | / | R22 | |||||||||||
| Power Supply Type | / | 3PH-380V-50HZ | |||||||||||
| Safety Protection Device | / | Overload、Inverse Phase、High/Low Pressure、Low Level、Antifreeze Protection, etc | |||||||||||
| Compressor | Power | KW | 2.25 | 3.75 | 3*2 | 3.75*2 | 7.5+3.75 | 7.5*2 | 9.4*2 | 7.5*3 | 7.5*4 | 9*4 | 7.5*6 |
| Current | A | 4.8 | 9.2 | 15.2 | 17.2 | 41.3 | 36 | 50 | 54 | 66 | 80 | 99 | |
| Pump | Flow | m³/h | 4 | 4 | 8 | 8 | 12 | 16 | 20 | 36 | 36 | 36 | 36 |
| Phead | m | 22 | 22 | 27 | 27 | 31 | 33 | 21 | 20 | 20 | 20 | 20 | |
| Power | KW | 0.55 | 0.55 | 1.1 | 1.3 | 1.85 | 2.6 | 2.2 | 4 | 4 | 4 | 4 | |
| Condenser | Type | / | MCHE Or Finned Tubes | ||||||||||
| Air Flow | m³/h | 3000 | 5000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | 40000 | 50000 | 60000 | |
| Fan Power | KW | 0.24 | 0.4 | 0.64 | 0.8 | 1.2 | 1.6 | 2 | 2.4 | 3.2 | 3.8 | 4 | |
| Evaporator | Type | / | Submerged Coil Type | Dny Shell And Tube Type | |||||||||
| In/Out Pipe Size | Inch | DN25 | DN25 | DN40 | DN50 | DN50 | DN50 | DN65 | DN65 | DN80 | DN80 | DN80 | |
| Tank Volume | L | 45 | 50 | 110 | 110 | 200 | 260 | 310 | 220 | 255 | 280 | 350 | |
| Size | Length | mm | 960 | 1050 | 1480 | 1480 | 1880 | 2000 | 2000 | 2400 | 2100 | 2450 | 3400 |
| Width | mm | 560 | 610 | 720 | 720 | 800 | 900 | 1000 | 1100 | 1600 | 1750 | 1800 | |
| Height | mm | 1250 | 1300 | 1550 | 1550 | 1700 | 1800 | 1950 | 1950 | 1850 | 2050 | 2100 | |
Products Detail
Frequently Asked Questions
Q
What is the difference between an air-cooled chiller and a water-cooled chiller?
The key difference lies in how heat is rejected. An air-cooled chiller uses an air-cooled condenser with axial fans to dissipate heat directly into the atmosphere, eliminating the need for a cooling tower or additional water supply. A water-cooled chiller relies on a separate cooling tower and condenser water loop. Air-cooled chillers are generally easier to install and maintain, making them ideal for locations where water resources are limited.
Q
What refrigerant does this air-cooled chiller use, and is it safe?
This chiller uses R22 refrigerant. R22 is a widely used HCFC refrigerant with stable performance and good thermodynamic properties. It is suitable for a broad range of industrial cooling applications. The system is equipped with comprehensive safety protection devices including overload protection, high/low pressure protection, antifreeze protection, and inverse phase protection to ensure safe operation.
Q
What industries are air-cooled water chillers most suitable for?
Air-cooled water chillers are widely used across many industries, including plastics injection molding, chemical and pharmaceutical processing, CNC machining and laser equipment, food and beverage production, electronics and semiconductor manufacturing, and energy and metallurgy applications such as transformer oil cooling. Any process that requires precise and stable temperature control can benefit from this type of chiller.
Q
How is the control system of this chiller configured?
The chiller supports both imported microcomputer control and PLC control (optional). It also offers optional RS485 communication capability, which enables integration with factory automation systems for remote monitoring and automatic management. Electrical components are sourced from leading brands including Siemens, Schneider, LG, and Moeller, ensuring reliability and longevity.
Q
What models are available and how do I choose the right capacity?
The product range includes 11 models from SC-03AS to SC-60AD, with cooling capacities ranging from 8.39 KW to 181.68 KW. To select the correct model, you should calculate the total heat load of your process equipment, factor in ambient temperature conditions, and consider future capacity requirements. Our technical team can assist you in selecting the optimal model based on your specific application requirements.
Q
Does the chiller require professional personnel for maintenance and repairs?
No. This chiller is designed with user-friendly fault display and diagnostic functions, allowing operators to identify and address common issues without requiring specialized technical personnel. The system's integrated safety protection and clear fault indicators simplify routine maintenance. However, for major repairs or refrigerant handling, it is recommended to consult a qualified technician.