Leave Your Message

China Air Cooled Water Chiller - Efficient Cooling Solutions from Reliable Suppliers and Factory

Discover our high-efficiency water chiller, a compact unit that integrates a refrigeration system, water tank, and water pump, making installation convenient and straightforward. This innovative product effectively cools circulating water to a desired low temperature through an advanced refrigeration process. Ideal for providing a stable low-temperature water source for industrial equipment, our water chiller is the perfect solution for manufacturers seeking reliable cooling. As a leading supplier and factory in China, we are dedicated to delivering superior products that meet your industrial cooling needs

    Product Feature
    • Adopt compressor imported from Europe and America
    • The copper pipe adopts oxygen free welding method
    • RS485 communication function to realize automatic management (optional)
    • Imported advanced components with long service life
    • Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
    • Control mode: imported microcomputer or PLC control (optional)
    • Perfect safety protection, fault display, repair and maintenance without professional personnel
    • High efficiency evaporator and condenser can save energy by more than 30%
    Working Principle and System Components
    1 Refrigeration Cycle (consistent with all compression refrigeration systems)
    • Refrigerant absorbs heat from the chilled water in the evaporator, vaporizing into a gas.
    • The low-temperature, low-pressure refrigerant vapor is compressed into a high-temperature, high-pressure gas by the compressor.
    • The high-temperature, high-pressure gas enters the air-cooled condenser, where it releases heat and condenses into a high-pressure liquid through forced convection from fan-driven ambient air.
    • The high-pressure liquid passes through the expansion valve, throttling into a low-temperature, low-pressure wet vapor, which re-enters the evaporator, completing the cycle.
    2 Core Difference — The Air-Cooled Condenser
    • This is the fundamental distinction between air-cooled and water-cooled chillers. It consists of copper tube-aluminum fin coil arrays and one or multiple high-power axial fans.
    • The fans force air across the finned coils, transferring heat from the high-temperature refrigerant inside the tubes to the atmosphere.
    3 System Composition (Highly Integrated)
    • Main Unit: The compressor, air-cooled condenser, evaporator, expansion valve, and control system are all integrated within a single steel frame.
    • Auxiliary Components:
    • Chilled Water Circulation Pump: Typically built into the water tank or provided as an external pump set.
    • Insulated Water Tank: Stores chilled water and acts as a buffer for system water volume and temperature stability.
    • Electrical Control Cabinet: Integrates control, protection, and display functions.
    Typical Industrial Applications
    🏭
    Plastics Industry Cooling for injection molding machine molds, directly impacting product quality and cycle time.
    ⚗️
    Chemical & Pharmaceutical Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
    🔧
    Machining & Lasers Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
    🍶
    Food & Beverage Cooling for mixing, fermentation, and packaging processes in production lines.
    💡
    Electronics Industry Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
    ⚡
    Energy & Metallurgy Transformer oil cooling, blast furnace auxiliary system cooling.
    16
    15
    14
    Schematic Diagram
    Schematic Diagram
    Specification
    Parameter UNIT MODEL
    SC-03AS SC-05AS SC-08AS SC-10AD SC-15AD SC-20AD SC-25AD SC-30AD SC-40AD SC-50AD SC-60AD
    Cooling Capacity Kcal/h 7216 11990 18748 24089 37965 50808.8 61683 74992 97678 116521 156249
    KW 8.39 13.95 21.8 28.01 44.15 59.08 71.72 87.2 113.58 135.49 181.68
    Power Input KW 3.6 5.5 8.6 11 17 22.8 27.7 33.7 42.8 51.1 68.8
    Running Current A 8.8 13.4 20.9 26.7 41.3 55.4 63.1 76.8 97.5 116.5 143.1
    Refrigerant / R22
    Power Supply Type / 3PH-380V-50HZ
    Safety Protection Device / Overload、Inverse Phase、High/Low Pressure、Low Level、Antifreeze Protection, etc
    Compressor Power KW 2.25 3.75 3*2 3.75*2 7.5+3.75 7.5*2 9.4*2 7.5*3 7.5*4 9*4 7.5*6
    Current A 4.8 9.2 15.2 17.2 41.3 36 50 54 66 80 99
    Pump Flow m³/h 4 4 8 8 12 16 20 36 36 36 36
    Phead m 22 22 27 27 31 33 21 20 20 20 20
    Power KW 0.55 0.55 1.1 1.3 1.85 2.6 2.2 4 4 4 4
    Condenser Type / MCHE Or Finned Tubes
    Air Flow m³/h 3000 5000 8000 10000 15000 20000 25000 30000 40000 50000 60000
    Fan Power KW 0.24 0.4 0.64 0.8 1.2 1.6 2 2.4 3.2 3.8 4
    Evaporator Type / Submerged Coil Type Dny Shell And Tube Type
    In/Out Pipe Size Inch DN25 DN25 DN40 DN50 DN50 DN50 DN65 DN65 DN80 DN80 DN80
    Tank Volume L 45 50 110 110 200 260 310 220 255 280 350
    Size Length mm 960 1050 1480 1480 1880 2000 2000 2400 2100 2450 3400
    Width mm 560 610 720 720 800 900 1000 1100 1600 1750 1800
    Height mm 1250 1300 1550 1550 1700 1800 1950 1950 1850 2050 2100
    Products Detail
    air cooled water chiller
    industrial water chiller
    Water chiller
    Frequently Asked Questions
    QWhat is an air-cooled water chiller and how does it work?
    An air-cooled water chiller is a refrigeration system that uses ambient air — driven by axial fans across finned copper-tube coil condensers — to dissipate heat from the refrigerant. The refrigerant absorbs heat from process water in the evaporator, is compressed, releases heat through the air-cooled condenser, and then cycles back through the expansion valve, continuously cooling the circulating chilled water.
    QWhat is the difference between an air-cooled chiller and a water-cooled chiller?
    The core difference lies in the condenser type. An air-cooled chiller rejects heat directly to the atmosphere via fans and finned coils, requiring no cooling tower or additional water supply. A water-cooled chiller uses a water-cooled condenser connected to a cooling tower, which offers higher efficiency but requires more infrastructure and water resources. Air-cooled models are easier to install and maintain.
    QWhat industries are air-cooled water chillers suitable for?
    Air-cooled water chillers are widely used across many industries, including plastics (injection molding cooling), chemical and pharmaceutical processing, CNC machining and laser equipment cooling, food and beverage production, electronics and semiconductor manufacturing, as well as energy and metallurgy applications such as transformer oil cooling.
    QWhat cooling capacity models are available and how do I choose the right one?
    Models range from SC-03AS (8.39 KW) to SC-60AD (181.68 KW), covering a wide range of industrial cooling demands. To select the correct model, calculate the total heat load of your process (in KW or Kcal/h), consider the ambient temperature at your installation site, and match it to the appropriate model's cooling capacity. Our technical team can assist with load calculations and model selection.
    QWhat safety protection features are built into the chiller?
    The chiller is equipped with comprehensive safety protection including overload protection, inverse phase protection, high/low pressure protection, low water level protection, and antifreeze protection. The microcomputer or PLC control system provides fault display and diagnostics, allowing maintenance without requiring specialized personnel on-site.
    QCan the chiller be integrated into an automated management system?
    Yes. The chiller supports RS485 communication (optional), enabling integration with building management systems (BMS) or factory automation platforms for remote monitoring, parameter adjustment, and automated management. The control system can be configured with either an imported microcomputer controller or a PLC-based control system depending on your requirements.