China Air Cooled Water Chiller - Efficient Cooling Solutions from Leading Suppliers & Factory
Product Feature
- Adopt compressor imported from Europe and America
- The copper pipe adopts oxygen free welding method
- RS485 communication function to realize automatic management (optional)
- Imported advanced components with long service life
- Siemens SCHNEIDER · LG · MOELLER · West is adopted for electrical appliances
- Control mode: imported microcomputer or PLC control (optional)
- Perfect safety protection, fault display, repair and maintenance without professional personnel
- High efficiency evaporator and condenser can save energy by more than 30%
Working Principle and System Components
1
Refrigeration Cycle (consistent with all compression refrigeration systems)
- Refrigerant absorbs heat from the chilled water in the evaporator, vaporizing into a gas.
- The low-temperature, low-pressure refrigerant vapor is compressed into a high-temperature, high-pressure gas by the compressor.
- The high-temperature, high-pressure gas enters the air-cooled condenser, where it releases heat and condenses into a high-pressure liquid through forced convection from fan-driven ambient air.
- The high-pressure liquid passes through the expansion valve, throttling into a low-temperature, low-pressure wet vapor, which re-enters the evaporator, completing the cycle.
2
Core Difference — The Air-Cooled Condenser
- This is the fundamental distinction between air-cooled and water-cooled chillers. It consists of copper tube-aluminum fin coil arrays and one or multiple high-power axial fans.
- The fans force air across the finned coils, transferring heat from the high-temperature refrigerant inside the tubes to the atmosphere.
3
System Composition (Highly Integrated)
- Main Unit: The compressor, air-cooled condenser, evaporator, expansion valve, and control system are all integrated within a single steel frame.
- Auxiliary Components:
- Chilled Water Circulation Pump: Typically built into the water tank or provided as an external pump set.
- Insulated Water Tank: Stores chilled water and acts as a buffer for system water volume and temperature stability.
- Electrical Control Cabinet: Integrates control, protection, and display functions.
Typical Industrial Applications
🏭
Plastics Industry
Cooling for injection molding machine molds, directly impacting product quality and cycle time.
⚗️
Chemical & Pharmaceutical
Cooling exothermic reactions in process vessels, controlling reaction rates and safety.
🔧
Machining & Lasers
Cooling for CNC machine spindles, laser sources, and welding equipment, ensuring precision and longevity.
🍶
Food & Beverage
Cooling for mixing, fermentation, and packaging processes in production lines.
💡
Electronics Industry
Cooling for semiconductor manufacturing, ultrasonic cleaning, and testing equipment.
⚡
Energy & Metallurgy
Transformer oil cooling, blast furnace auxiliary system cooling.
Schematic Diagram
Specification
| Parameter | UNIT | MODEL | |||||||||||
| SC-03AS | SC-05AS | SC-08AS | SC-10AD | SC-15AD | SC-20AD | SC-25AD | SC-30AD | SC-40AD | SC-50AD | SC-60AD | |||
| Cooling Capacity | Kcal/h | 7216 | 11990 | 18748 | 24089 | 37965 | 50808.8 | 61683 | 74992 | 97678 | 116521 | 156249 | |
| KW | 8.39 | 13.95 | 21.8 | 28.01 | 44.15 | 59.08 | 71.72 | 87.2 | 113.58 | 135.49 | 181.68 | ||
| Power Input | KW | 3.6 | 5.5 | 8.6 | 11 | 17 | 22.8 | 27.7 | 33.7 | 42.8 | 51.1 | 68.8 | |
| Running Current | A | 8.8 | 13.4 | 20.9 | 26.7 | 41.3 | 55.4 | 63.1 | 76.8 | 97.5 | 116.5 | 143.1 | |
| Refrigerant | / | R22 | |||||||||||
| Power Supply Type | / | 3PH-380V-50HZ | |||||||||||
| Safety Protection Device | / | Overload、Inverse Phase、High/Low Pressure、Low Level、Antifreeze Protection, etc | |||||||||||
| Compressor | Power | KW | 2.25 | 3.75 | 3*2 | 3.75*2 | 7.5+3.75 | 7.5*2 | 9.4*2 | 7.5*3 | 7.5*4 | 9*4 | 7.5*6 |
| Current | A | 4.8 | 9.2 | 15.2 | 17.2 | 41.3 | 36 | 50 | 54 | 66 | 80 | 99 | |
| Pump | Flow | m³/h | 4 | 4 | 8 | 8 | 12 | 16 | 20 | 36 | 36 | 36 | 36 |
| Phead | m | 22 | 22 | 27 | 27 | 31 | 33 | 21 | 20 | 20 | 20 | 20 | |
| Power | KW | 0.55 | 0.55 | 1.1 | 1.3 | 1.85 | 2.6 | 2.2 | 4 | 4 | 4 | 4 | |
| Condenser | Type | / | MCHE Or Finned Tubes | ||||||||||
| Air Flow | m³/h | 3000 | 5000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | 40000 | 50000 | 60000 | |
| Fan Power | KW | 0.24 | 0.4 | 0.64 | 0.8 | 1.2 | 1.6 | 2 | 2.4 | 3.2 | 3.8 | 4 | |
| Evaporator | Type | / | Submerged Coil Type | Dny Shell And Tube Type | |||||||||
| In/Out Pipe Size | Inch | DN25 | DN25 | DN40 | DN50 | DN50 | DN50 | DN65 | DN65 | DN80 | DN80 | DN80 | |
| Tank Volume | L | 45 | 50 | 110 | 110 | 200 | 260 | 310 | 220 | 255 | 280 | 350 | |
| Size | Length | mm | 960 | 1050 | 1480 | 1480 | 1880 | 2000 | 2000 | 2400 | 2100 | 2450 | 3400 |
| Width | mm | 560 | 610 | 720 | 720 | 800 | 900 | 1000 | 1100 | 1600 | 1750 | 1800 | |
| Height | mm | 1250 | 1300 | 1550 | 1550 | 1700 | 1800 | 1950 | 1950 | 1850 | 2050 | 2100 | |
Products Detail
Frequently Asked Questions
Q
What is an air-cooled water chiller and how does it work?
An air-cooled water chiller is a refrigeration system that cools water by transferring heat to the surrounding air via an air-cooled condenser with finned coils and axial fans. The refrigerant circulates through the compressor, condenser, expansion valve, and evaporator in a closed loop to continuously chill the process water.
Q
What is the difference between air-cooled and water-cooled chillers?
The primary difference lies in the condenser type. Air-cooled chillers use ambient air and fans to dissipate heat, making them easier to install and maintain with no cooling tower required. Water-cooled chillers use a cooling tower and water circuit to reject heat, typically offering higher efficiency in large-scale applications.
Q
What industries are air-cooled water chillers suitable for?
Air-cooled water chillers are widely used across plastics injection molding, chemical and pharmaceutical processing, CNC machining and laser equipment, food and beverage production, electronics manufacturing, and energy and metallurgy sectors — anywhere precise temperature control is required.
Q
What refrigerant is used and what is the power supply requirement?
These air-cooled chillers use R22 refrigerant and require a 3-phase, 380V, 50Hz power supply. The units are equipped with comprehensive safety protection including overload, inverse phase, high/low pressure, low level, and antifreeze protection devices.
Q
Can the chiller be controlled remotely or integrated into an automation system?
Yes. The chiller supports optional RS485 communication for remote monitoring and automatic management integration. The control mode can be configured with an imported microcomputer controller or PLC control system, making it compatible with modern industrial automation environments.
Q
How energy-efficient are these air-cooled water chillers?
Thanks to high-efficiency evaporators and condensers, these chillers can reduce energy consumption by more than 30% compared to conventional units. The use of European and American imported compressors and advanced components also ensures stable long-term performance and a longer service life.